The portable bio sensor can detect endotoxin in blood serum using a standard addition method, providing results within 10 minutes
The National Institute of Technology Calicut developed eight distinct sensor architectures and a sensitive, low-cost, portable device for detecting endotoxins rapidly and accurately, which in the future can be used at the bedside of the patient.
Seven of them were developed by Dr N Sandhyarani, Professor, National Institute of Technology Calicut and her team employed electrochemical detection and one utilised optical detection. In all the sensors, appropriately modified nanomaterials such as gold atomic clusters or nanoparticles, CuO, or Cu nanoclusters, MoS2, reduced graphene oxide, or carbon nanotubes were used for enhancing the sensitivity.
In a paper published in the journal Langmuir, the team has demonstrated a highly sensitive electrochemical sensor chip designed for the selective detection of Lipopolysaccharide (LPS), which is compatible with a portable analyser for on-site detection. The sensor is fabricated using functionalised CNT (fCNT) and copper(I) oxide nanoparticles (Cu2O).
The specific binding of endotoxin to LPS-binding Aptamers or polymyxin B was used to improve selectivity. All the sensors have exhibited high selectivity and detected endotoxin in the presence of other interfering compounds. The presence of endotoxin is also detected in pharmaceutical drug-Biphasic isophane insulin, fruit juices, and whole blood by the standard addition method. Endotoxin recovery was within 2 per cent error in all the cases.
Two of these electrochemical platforms demonstrated versatility by enabling the sensitive detection of Gram-negative bacteria, specifically E. coli, in water samples.
The analysis demonstrates that the quantification of E. coli using these platforms is comparable to traditional biological methods and also reduces analysis time. This highlights their potential for efficient water quality monitoring.
The team has designed, built, and tested a portable and cost-effective electrochemical biosensor prototype specifically for endotoxin detection. This device detects endotoxin in blood serum using a standard addition method, providing results within 10 minutes.
This research, supported by the Nano Mission of the Department of Science and Technology (DST), has resulted in seven publications in reputed international journals such as Biosensors and Bioelectronics, Langmuir (two cover pages), Analyst, and Analytica Chimica Acta and one granted patent for the prototype device.
The researchers are now improving the sensitivity of the prototype device by refining the electronic design to enable a highly sensitive and selective point-of-care (POC) device suitable for rapid, bedside biomarker detection.